Diesel Portable Marine Power Weichai Wh25 Ccfj2000j-WMV Generator Set

Customization: Available
After-sales Service: Global Service
Warranty: 1 Year Warranty

Product Description

Basic Info
Model NO.
WH25 CCFJ2000J-WMV
Type
Basic Diesel Generator
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
300-1000rpm
Conditions of Use
Marine
Usage
Common Units, Emergency Crew
Landuse Type of Unit
Ordinary
Excitation Mode
AC Rotating Exciter
Certificate
CCS
Delivery Time
25 Days
Color
Green, Black, Blue
Power
2000kw
Weight
36852kg
Transport Package
Plywood Case
Specification
7430*2120*2929
Trademark
Weichai / Huide
Origin
Jiangsu
HS Code
85021200
Production Capacity
200PCS Per Month
Product Description

Diesel Portable Marine Power Weichai WH25 CCFJ2000J-WMV Generator Set

Weichai marine generator sets are mainly divided into primary and emergency generator sets according to their uses. The power range of primary generator sets is 16-8730kW, and the power range of emergency generator sets is 30-900kW. The primary generator sets include diesel and gas generator set according to their fuel. The diesel generator sets include Yangchai series, Deutz series, Landking series, Baudouin series, 170 series and CW200/250 series products. The gas generator set mainly includes Deutz series. The manufacture and test of the generator sets comply with the general technical conditions of GB/T13032-2010 Marine Diesel Generator Set.

Notes: This model portfolio and introduction is mainly about 50Hz products, and 60Hz products with corresponding powers can also be produced.

Series Model Primary power/kW Continuous power/kW Diesel generator model Generator Brand Starting system Mode of speed regulation Emission stage Dimensions/mm Net weight/kg
X6170 CCFJ250J-W* 250 250 X6170ZCD280-1 Siemens
Kang Fu
electric starter/air starter Mechanical/electronic IMO2 3288*1255*1977 5152
CCFJ300J-W* 300 300 X6170ZCD330-1 IMO2 3241*1255*1977 5307
CCFJ350J-W* 350 350 X6170ZCD390-4 IMO2 3400*1236*2001 5230
CCFJ400J-W* 400 400 X6170ZCD440-4 IMO2 3466*1236*2001 5282
CCFJ450J-W* 450 400 X6170ZCD500-5 IMO2 3728*1406*2004 6513
CCFJ500J-W* 500 400 X6170ZCD556-5 IMO2 3728*1406*2004 6513
CCFJ500J-W* 500 450 X6170ZCD601-5 IMO2 3728*1406*2004 6513
8170 CCFJ400J-W* 400 400 8170ZCD441-1 Siemens
Kang Fu
electric starter/air starter electronic IMO2 4424*1493*2277 6251
CCFJ500J-W* 500 500 8170ZCD600-5 IMO2 4418*1406*2004 7263
CCFJ400J-W* 400 400 8170ZCD441-1* Siemens
Kang Fu
electric starter Electronical-controlled common rail IMO2 4424*1493*2277 6251
CCFJ450J-W* 450 450 8170ZCD490-1* IMO2 4418*1406*2004 7263
CCFJ500J-W* 500 500 8170ZCD600-5* IMO2 4418*1406*2004 7263
6WH17* CCFJ450J-W* 450 450 6WH17CD539-1 Siemens electric starter Electronical-controlled common rail IMO2 4435*1550*1715 8150
CCFJ500J-W* 500 500 6WH17CD638-2 IMO2 4435*1550*1715 8150
CCFJ550J-W* 550 500 6WH17CD660-5 IMO2 4435*1550*1715 8150
CCFJ600J-W* 600 500 6WH17CD809-5 IMO2 4435*1550*1715 8150
12WH17* CCFJ800J-W* 800 800 12WH17CD990-1 Siemens electric starter Electronical-controlled common rail IMO2 5315*1600*1782 12868
CCFJ1000J-W* 1000 900 12WH17CD1210-2 IMO2 5315*1600*1782 12868
CCFJ1000J-W* 1000 1000 12WH17CD1265-5 IMO2 5315*1600*1782 12868
CCFJ1200J-W* 1200 1200 12WH17CD1485-5 IMO2 5315*1600*1782 12868
CCFJ1500J-W* 1500 1300 12WH17CD1782-5 IMO2 5315*1600*1782 12868
CW200 CCFJ450J-WMW - 450 CW6200ZD-39 Siemens air starter Electronical-controlled common rail IMO2 4550*1800*2450 11500
CCFJ500J-WMW - 500 CW6200ZD IMO2 4550*1800*2450 11500
CCFJ600J-WMV - 600 XCW6200ZD IMO2 4600*1800*2450 12000
CCFJ700J-WMV - 700 XCW6200ZD-10 IMO2 4600*1800*2450 12500
CCFJ800J-WMV - 800 XCW8200ZD-1 IMO2 5300*2000*2500 14000
CCFJ900J-WMV - 900 XCW8200ZD-10 IMO2 5300*2000*2500 14000
CCFJ1000J-WMV - 1000 XCW8200ZD-2 IMO2 5300*2000*2500 14000
CCFJ1200J-WMV - 1200 XCW12V200ZD IMO2 5400*1900*3000 20000
CCFJ1500J-WMV - 1500 CW16V200ZD IMO2 6500*1900*3000 25000
CW250 CCFJ1200J-WMX - 1200 CW6250ZLD Siemens electric starter Mechanical/electronic IMO2 6150*1280*3100 24150
CCFJ1700J-WMX - 1700 CW8250ZLD IMO2 7200*1280*3100 28000
WH20* CCFJ600J-WM* - 600 6WH20LCD700-7.5 Siemens air starter Mechanical/electronic IMO2 5947*1600*261 18562
CCFJ700J-WM* - 700 6WH20LCD800-7.2 IMO2 5947*1600*2616 18562
CCFJ800J-WM* - 800 6WH20LCD900-7.5 IMO2 5947*1600*2616 18562
CCFJ900J-WM* - 900 6WH20LCD1000-1 IMO2 5947*1600*2616 18562
CCFJ900J-WM* - 900 6WH20LCD1000-9 IMO2 5947*1600*2616 18562
CCFJ1100J-WM* - 1100 6WH20LCD1200-1 IMO2 5947*1600*2616 18562
CCFJ1200J-WM* - 1200 6WH20LCD1320-1 IMO2 5947*1600*2616 18562
CCFJ900J-WM* - 900 8WH20LCD1000-7.5 IMO2 7156*1750*2694 22580
CCFJ900J-WM* - 900 8WH20LCD1000-7.2 IMO2 7156*1750*2694 22580
CCFJ1100J-WM* - 1100 8WH20LCD1200-7.5 IMO2 7156*1750*2694 22580
CCFJ1100J-WM* - 1100 8WH20LCD1200-9 IMO2 7156*1750*2694 22580
CCFJ1250J-WM* - 1250 8WH20LCD1440-1 IMO2 7156*1750*2694 22580
CCFJ1250J-WM* - 1250 8WH20LCD1440-9 IMO2 7156*1750*2694 22580
CCFJ1400J-WM* - 1400 8WH20LCD1600-1 IMO2 7156*1750*2694 22580
WH25* CCFJ1100J-WM* - 1100 6WH25LCD1296-7.2 Siemens air starter Mechanical/electronic IMO2 7356*1850*2929 30560
CCFJ1200J-WM* - 1200 6WH25LCD1350-7.5 IMO2 7356*1850*2929 30560
CCFJ1300J-WM* - 1300 6WH25LCD1470-7.5 IMO2 7356*1850*2929 30560
CCFJ1500J-WM* - 1500 6WH25LCD1620-9 IMO2 7356*1850*2929 30560
CCFJ1600J-WM* - 1600 6WH25LCD1800-1 IMO2 7356*1850*2929 30560
CCFJ1600J-WM* - 1600 6WH25LCD1800-9 IMO2 7356*1850*2929 30560
CCFJ1800J-WM* - 1800 6WH25LCD2010-1 IMO2 7356*1850*2929 30560
CCFJ1600J-WM* - 1600 8WH25LCD1800-7.5 IMO2 7430*2120*2929 36852
CCFJ1600J-WM* - 1600 8WH25LCD1800-7.2 IMO2 7430*2120*2929 36852
CCFJ1800J-WM* - 1800 8WH25LCD2000-7.5 IMO2 7430*2120*2929 36852
CCFJ2000J-WM* - 2000 8WH25LCD2200-1 IMO2 7430*2120*2929 36852
CCFJ2000J-WM* - 2000 8WH25LCD2200-9 IMO2 7430*2120*2929 36852
CCFJ2000J-WM* - 2200 8WH25LCD2450-1 IMO2 7430*2120*2929 36852
Remark:
I. Definition of power:
Normal power of the generator set:
1. The average load rate exceeding 24 hours of running does not exceed 70%.
2. Within every 12h, with an overload by 10%, the engine can run for 1h.
3. The annual running time is not limited.

Continuous power of the generator set:
1. The annual running time is not limited.
2. Run under constant 100% load.
3. Every 12h, can overload 10% operation for 1h.

II. The requirements of power matching:
1. For ship types with annual running time exceeding 3000h or large impact load, such as seine fishing with light, refrigerating, rake and prick, floating crane, sand suction boat and wind power installation, the model shall be selected according to the continuous power of the generator set.
2. For ship types such as inland river transport ships, coastal fishing boats and high-speed boats with domestic electricity or auxiliary pumps as the main load, the model can be selected according to the normal power of the generator set.
3. For ship types such as Light lure fish ships, rake barbed fishing boats and floating crane class ships, sand suction, lifting class engineering ships, It is recommended to contact with the application department before selection.

III. Product Power Description:
1. CW200 series, CW250 series, WH620 series, WH20 series, WH25 series, WH28 series common power and sustained power value is the same.
2. High speed machine series, WHM6160 series, 170 series and WH17 series are divided into common power and continuous power.
3. Dimension and weight are for reference only.
4. The delivery date of products marked with * shall be subject to the reply of the manufacturer. Product parameters and model portfolio are for reference only. Please contact relevant personnel for official information on delivery time and fishing boat model portfolio.
Product Gallery
Frequently Asked Questions
What is the power range of Weichai marine generator sets?
The power range of the primary generator sets is 16-8730kW, while the power range of emergency generator sets is 30-900kW.
Which standards do these marine generator sets comply with?
The manufacture and testing of the generator sets strictly comply with the general technical conditions of GB/T13032-2010 Marine Diesel Generator Set.
What is the difference between Normal Power and Continuous Power?
Normal power allows an average load rate of up to 70% over 24 hours of operation. Continuous power has no annual running limit under a constant 100% load. Both options support a 10% overload operation for 1 hour within every 12-hour period.
Can 60Hz marine generator sets be manufactured?
Yes. While the standard model portfolio is presented for 50Hz products, 60Hz products with corresponding powers can be custom produced upon request.
Which ship types require selection based on Continuous Power?
It is recommended to select models based on continuous power for ship types with an annual running time exceeding 3000 hours or those subjected to large impact loads, such as light seine fishing, refrigerating vessels, rake and prick boats, floating cranes, sand suction boats, and wind power installation vessels.
What types of starting systems and speed regulations are available?
Depending on the specific model, starting options include electric starter or air starter systems. Speed regulation modes range from mechanical and electronic controls to advanced electronical-controlled common rail systems.